Jaws Only IMRT
TREAT YOUR PATIENTS USING IMRT WITHOUT THE EXPENSE OF AN MLC
Now you can develop plans comparable to traditional IMRT plans, without using a Multi-Leaf Collimator (MLC). The patented Prowess Panther™ Jaws-Only IMRT is ideal for facilities that wish to create IMRT plans, but do not have an MLC.
Prowess' unique Jaws-Only IMRT system uses only the jaws of the collimator to shape the beam, effectively eliminating the need for any other beam-shaping device, including an MLC or block.
POTENTIAL SAVING OF HUNDREDS OF THOUSANDS OF DOLLARS
An MLC attachment for a linear accelerator can cost several hundred thousand dollars. Many clinics have delayed the implementation of IMRT treatment planning because of the significant investment in additional equipment necessary to deliver IMRT plans. Prowess recognizes the need for a less expensive way of delivering IMRT. The new Prowess Panther™ Jaws-Only IMRT product makes it possible for cancer treatment centers to begin offering IMRT, without incurring the additional equipment costs of an MLC.
Determining whether a Record & Verify system (R&V) and an Auto Field Sequencer (AFS) are necessary would depend on the number of treatments being delivered by your facility and the complexity of the plans.
BENEFITS OF DAO JAWS-ONLY IMRT
- Improved plan quality
- Improved patient comfort due to reduced treatment time
- No need go in and out of the treatment room to replace blocks / wedges during treatment.
- No electron contamination created from the blocks / wedges
- The motor of the Jaws have been proven to be very reliable, and easily lasts for 5 or more years
DAO IMRT – Additional features
- The delivery constraints on individual aperture shapes (formed either by MLC leaves or by movable Jaws) are directly taken into account into optimization process as well as the weights of the individual aperture shapes. There is no conversion from fluence maps to aperture shapes.
- Simulated Annealing based optimization
- Quick convergence ability of the algorithm reduces the time for optimization
- 3mm x 3mm x CT Slice Thickness Voxel Spacing
- Optimization option is a license controlled module that opens up as an additional window in the Prowess Panther treatment planning system.
- Single window interface displaying the following features
- Interactive, Real time DVH graphs display.
- Graphical User interface to set and alter constraint settings in real time
- Real time objective function in graphical display
- Equivalent Uniform Dose (EUD) representation
- Instant classification of organs into any of the three categories
- Target Volumes
- Critical Volumes
- Ignored Volumes
- User could add and edit any of the following definitions for the constraints either via GUI or keyboard entry
- Points Less Than
- Points Greater Than
- Points Between
- Points Outside
- DVH Below
- DVH Above
- EUD Less Than
- EUD Greater Than
- Individual weighting for each constraints
- Graphs can be viewed in Black or White background option
- Option to store current constraint set into library and retrieve for future usage
- Optimization can be paused and resumed as needed
- On the fly optimization – Change constraints and weighting without pausing the optimization.
- Customizable Number of Segments per beam
- Display of fluence maps for each selected segment of the beam in BEV
- Tabular display of sequential fluences for the segments of each beam
- MU Display for each of the segment in total or per fraction options
- Ability to allow user to change the sequence of the segments in any of the beams
- Collapsed Cone Convolution Superposition with/without heterogeneity correction
- DVH and Monitor Units (MU) can be scaled by using a slide bar for easy plan normalization
- Constraints can be set for beam MU, segment MU and segment area
IMRT QA
- Customizable IMRT QA settings such as:
- Predefined isocenter
- Set gantry to point to floor
- Automatically start calculation
- Separate plan for each beam
- Single click export of IMRT plans to QA phantom
- Supports scanned QA Phantoms
- Supports Mapcheck, RadCal and other QA software
- Monitor Units (MU) can be edited
Recommended Hardware Requirements
- 2 x Quad-Core Xeon E5450 3GHz
- RAM Memory: 4 GB
- DVD±RW (±R DL) / DVD-RAM
- Hard Disk: 250GB
- Video Card: ATI Radeon HD2600 PRO
- Ethernet Card: Gigabit Ethernet
- Monitor: Capable of displaying (1280 x 1024 pixels) and 32 bit Color